Bosch Appliances Network Card D9210B User Manual

Access Control Interface Module D9210B  
Operation and Installation Guide  
 
D9210B  
Contents  
1.0  
1.1  
1.2  
1.3  
Introduction........................................................................................................................................................................................... 5  
Manual Organization ..........................................................................................................................................................5  
Other Literature Referenced ............................................................................................................................................5  
Documentation Conventions............................................................................................................................................5  
1.3.1 Type Styles Used in this Manual .....................................................................................................................................5  
1.3.2 Tips, Important Notes, Cautions and Warnings...........................................................................................................6  
1.4  
1.5  
2.0  
2.1  
FCC Notice ..........................................................................................................................................................................6  
Regulatory Listings.............................................................................................................................................................6  
D9210B Overview.............................................................................................................................................................................. 7  
System Description ............................................................................................................................................................7  
2.1.1 Operational Primer..............................................................................................................................................................7  
2.1.1.1 Outputs .................................................................................................................................................................................7  
2.1.1.2 Inputs.....................................................................................................................................................................................7  
2.1.1.3 Access Levels......................................................................................................................................................................8  
2.1.1.4 Skeds.....................................................................................................................................................................................8  
2.2  
2.3  
Physical Overview...............................................................................................................................................................9  
Basic Features, Displays and Reports...........................................................................................................................9  
2.3.1 Basic Features .................................................................................................................................................................9  
2.3.2 Displays and Reports...................................................................................................................................................... 10  
2.4  
2.5  
2.6  
Materials Included............................................................................................................................................................ 10  
Ordered Separately......................................................................................................................................................... 11  
Listings and Approval Information................................................................................................................................ 12  
2.6.1 Underwriters Laboratories (UL) .................................................................................................................................... 12  
2.6.2 Other Listings and Approvals........................................................................................................................................ 12  
3.0  
3.1  
3.2  
Installation...........................................................................................................................................................................................13  
System Planning............................................................................................................................................................... 13  
Procedure.......................................................................................................................................................................... 13  
3.2.1 Step 1: Mounting the Enclosure and Installing the D9210B................................................................................. 13  
3.2.2 Step 2: Pulling and Marking the Wires....................................................................................................................... 14  
3.2.3 Step 3: Mounting............................................................................................................................................................. 16  
3.2.3.1 D9210BLC........................................................................................................................................................................ 16  
3.2.3.2 D9210B ............................................................................................................................................................................. 16  
3.2.3.3 D9210BC.......................................................................................................................................................................... 16  
3.2.4 Step 4: Door Contact (Onboard) Point, Terminals 9 and 10................................................................................ 16  
3.2.5 Step 5: Door Lock, Terminals 2, 3 and 4................................................................................................................... 17  
3.2.6 Step 6: Request to Enter (RTE), Terminals 11 and 12........................................................................................... 17  
3.2.7 Step 7: Request to Exit (REX), Terminals 13 and 12.............................................................................................. 17  
3.2.8 Step 8: Enclosure Tamper Switch, Terminals 8 and 9............................................................................................ 17  
3.2.9 Step 9: Connecting the Card Reader, Terminals 12, 14, 15, 16, 17, and 18 .................................................. 18  
3.2.10 Step 10: Setting the Dipswitch and Tagging the Unit............................................................................................ 19  
3.2.11 Step 11 Connecting Power and SDI, Terminals 1, 3, 5, 6, and 7........................................................................ 20  
3.2.12 Step 12: Programming and Activating the D9210B ............................................................................................... 20  
3.2.13 Step 13: Testing the D9210B...................................................................................................................................... 21  
4.0  
4.1  
5.0  
Operation .............................................................................................................................................................................................23  
Door Release Application .............................................................................................................................................. 23  
Troubleshooting ...............................................................................................................................................................................25  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 3  
32206G  
 
D9210B  
Contents  
5.1  
LED Troubleshooting.......................................................................................................................................................25  
Appendix A: D9210B Terminal Quick Reference and Electrical Specifications..............................................................27  
Figures  
Figure 1: D9210B Access Control Interface Module................................................................................................................9  
Figure 2: Wiring Diagram for Typical D9210B Installation.....................................................................................................15  
Figure 3: Relay Installation .............................................................................................................................................................17  
Figure 4: D9210B DIP Switch (Factory Settings)....................................................................................................................19  
Figure 5: Power Supply and SDI Connections .........................................................................................................................20  
Figure 6: D9210B Door Release Application Connections...................................................................................................23  
Tables  
Table 1: D9210B Operation and Installation Guide Document Organization .....................................................................5  
Table 2: Other Literature Referenced............................................................................................................................................5  
Table 3: D9210B Diagnostic and Status LEDs..........................................................................................................................9  
Table 4: Typical Wire Planning Chart for the D9210B ...........................................................................................................14  
Table 5: Point Tolerance Voltages ...............................................................................................................................................16  
Table 6: Door Lock Strikes.............................................................................................................................................................17  
Table 7: UL Listed Compatible Readers for the D9210B ......................................................................................................18  
Table 8: D9210B Dipswitch Settings .........................................................................................................................................19  
Table 9: LED Troubleshooting Guide..........................................................................................................................................25  
Table 10: Terminal Quick Reference Guide and Electrical Specifications.........................................................................27  
D9210B Operation and Installation Guide  
32206G  
Page 4  
© 2002 Bosch Security Systems  
 
D9210B  
Introduction  
1.0 Introduction  
This document assumes that you have basic security system installation skills such as measuring voltages, stripping wire,  
making proper wire connections, and checking phone lines. It also assumes you are familiar with the proper installation  
of Bosch Security Systems Control/Communicator panels and the related programming tasks.  
The material and instructions in this document have been carefully checked for accuracy and are presumed to be reliable.  
However, Bosch Security Systems assumes no responsibility for inaccuracies and reserves the right to modify and revise  
this document without notice.  
1.1  
Document Organization  
This document is divided into five sections with one appendix. A summary of each section and appendix is detailed in the  
table below.  
Section  
Description  
1
2
3
4
5
Introduction – this section  
Overview – provides a functional overview of the D9210B.  
Installation – provides detailed installation and configuration instructions for the D9210B.  
Operation – provides information on the operation of the D9210B.  
Troubleshooting – provides a detailed troubleshooting table.  
Appendix Description  
D9210B Terminal Quick Reference and Electrical Specifications  
A
Table 1: D9210B Operation and Installation Guide Document Organization  
1.2  
Other Literature Referenced  
Throughout this document, references will be made to other documentation. For a more complete and detailed  
description of the D9210B Access Control Interface Module, see the following table that lists the complete part number for  
ordering purposes.  
Name of document  
P/N:  
32207  
32208  
------  
D9210B Program Entry Guide  
ACCESS Program Record Sheet  
Security System Owner’s Manual  
Table 2: Other Literature Referenced  
1.3  
Documentation Conventions  
These conventions are intended to call out important features, items, notes, cautions, and warnings that the reader  
should be aware of in reading this document.  
1.3.1 Type Styles Used in this Document  
To help identify important items in the text, the following type styles are used:  
Bold text  
usually indicates selections that you may use while programming your panel. It may also indicate  
an important fact that should be noted.  
Bold Italicized  
Italicized text  
used to denote notes, cautions and/or warnings  
Is used to reference the user to another part of this manual or another manual entirely. It is also  
used to symbolize names for records that the user will create.  
Courier Text  
Text that appears like this indicates what may appear on the D5200 Programmer display,  
command center/keypad or internal printer.  
[CAPITALIZED TEXT]  
Text like this is used to indicate to the user that a specific key should be pressed.  
Example: …press the [ESC] key…  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 5  
32206G  
 
D9210B  
Introduction  
1.3.2 Tips, Important Notes, Cautions and Warnings  
Throughout this document, helpful tips, important notes, cautions and warnings will be presented for the reader to keep  
in mind. These appear different from the rest of the text as follows;  
Important Notes - should be heeded for successful operation and programming. Also tips and shortcuts may  
be included here.  
Caution - These caution the operator that physical damage to the program and/or equipment may occur.  
Warning - These warn of the possibility of physical damage to the operator, program and/or equipment.  
Troubleshooting Tip – These provide tips in troubleshooting common problems that may occur.  
Technical Tip – These provide tips on setting up and configuration.  
Technical  
Tip  
1.4  
FCC Notice  
This equipment generates, uses and can radiate radio frequency energy. If not installed in accordance with the  
manufacturer’s instructions, it may cause interference to radio communications. It has been tested and found to comply  
with the specifications in Subpart J of Part 15 of FCC Rules for Class B Computing Devices.  
If this equipment causes interference to radio or television reception –– which can be determined by turning the  
equipment on and off –– the installer is encouraged to correct the interference by one or more of the following measures:  
1) Reorient the antenna of the radio/television, 2) Connect the AC transformer to a different outlet so the control panel  
and radio/television are on different branch circuits, 3) Relocate the control panel with respect to the radio/television.  
If necessary, the installer should consult an experienced radio/television technician for additional suggestions, or send for  
the “Interference Handbook” prepared by the Federal Communications Commission. This booklet is available from the  
U.S. Government Printing Office, Washington DC 20402, stock no. 004-000-00450-7.  
1.5  
Regulatory Listings  
UL 294  
UL 1076  
UL 609  
UL 864  
FCC 15B  
CSFM  
UL 365  
UL 1610  
D9210B Operation and Installation Guide  
32206G  
Page 6  
© 2002 Bosch Security Systems  
 
D9210B  
D9210B Overview  
2.0 D9210B Overview  
2.1  
System Description  
2.1.1 Operational Primer  
The D9210B is a fully supervised, addressable SDI bus device that allows access control integration for the D9412 (8  
doors) and D7412 (2 doors) panels. Each D9210B can store up to 986 user tokens (300 tokens for D7412), each with a  
different access level for each door. Authority for access is controlled by the level of the user, the time of day, the state of  
the door and the armed state of the area to which the D9210B. Each of the authority restrictions can be controlled  
through automatic and manual functions.  
Users can be added to the system either by local programming using the D5200, remote programming using the Remote  
Account Manager (RAM), or by adding tokens using the Add User function through the control center(s).  
The D9210B is not programmed using a local or remote programmer. The D9210B must be connected to the SDI bus to  
function properly and receive operational programming parameters and user data.  
2.1.1.1 Outputs  
Dry contact SPDT relay for 12/24 V strikes. The D136 removable relay provides a Normally Closed (NC), Common  
(Input voltage) and Normally Open (NO) output. When the relay is energized, the outputs switch to an opposite state.  
Buzzer Output. The buzzer output activates when the door sequence begins or if the door is left open for an extended  
period of time. It provides common to the negative side of the buzzer.  
+5 VDC reader output. The +5 V DC output is for ID readers that require a lower voltage than the +12 VDC readers. It  
provides a maximum of 150 mA.  
2.1.1.2 Inputs  
SDI input and output. SDI A (yellow) receives data from the SDI A of the panel. SDI B (green) returns data to the SDI B  
of the panel.  
12 VDC input. This input is used to power the D9210B and provides a connection for the 12 VDC reader and 12 VDC  
buzzer.  
Supervised zone input for the door contact. The zone input on the D9210B is used for the door contact that is physically  
mounted on the door to which the strike is connected.  
The input can be configured for shorts/opens on faults but is normal only when the 1000 k resistor is in the circuit.  
Unsupervised tamper input. The unsupervised tamper input is normal when open. Upon a short, the point number  
assigned to the supervised zone is reported as a MISSING PT### report.  
Unsupervised Request to Enter [RTE] and Request to Exit [REX] inputs. The [RTE] input and [REX] input are normally  
open inputs sharing the same common terminal. When momentarily shorted (500 ms) by a dry contact, input will  
initiate the door sequence. Typical applications include a N/O momentary push button or a N/O momentary relay  
activation from a Door motion detector device.  
The [REX] input generates Door Request to Exit and is used to exit the area assigned to the D9210B without  
having to use an ID. The [RTE] generates Door Request to Enter and is used to enter the area assigned to the  
D9210B.  
Programming REX Shunt Only and RTE Shunt Only allows you to initiate only the shunt and buzz when the [RTE] or  
[REX] inputs are shorted. This eliminates the need for a strike and would be used in applications where a push bar is used  
to open the door.  
It is advisable to assign a point number to the device used to activate the [RTE] and [REX] inputs (such as an infrared  
with addressable ZONEX). This ensures that the device is supervised.  
Unsupervised reader. The Weigand Reader input is a five wire input that supplies +5 VDC (use the +12 VDC terminal  
for 12-volt readers), negative, ground activation for the reader LED, [D1] and [D0] inputs for the card data.  
Two LEDs are provided to indicate that data is reaching the inputs from the reader when an ID is read. The IDs do not  
have to be valid to illuminate these LEDs, but the IDs do need to have a format that the reader can decipher.  
Normal Door Sequence. The Normal Door Sequence of the D9210B is initiated by a valid access granted (User ID) or  
door request [RTE/REX]. This initiates the strike, shunt and buzz time to activate the strike, shunt the point and create  
an event reporting the door sequence has begun.  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 7  
32206G  
 
D9210B  
D9210B Overview  
When the door is held open past the normal door sequence time, an extended door sequence time is initiated. This  
extended time extends the shunt and re-activates the buzzer. If programmed, CLOSE DOOR # will display at the control  
center assigned to the door.  
The normal door sequence will not activate if the interlock point is in an off normal (open or short) condition.  
The Interlock Point can be assigned to multiple door controllers. This is useful for applications that require doors to not  
activate when a point is faulted until the interlock point is normal.  
Door States. There are four door states for the D9210B. These door states can be controlled through the control center,  
the Remote Account Manager (R.A.M.), scheduled events (Skeds) and automatic programmable functions in the D9210B  
parameters.  
Locked Door. This state is considered a normal door state.  
Unlock Door. This state allows the door to be opened for free access.  
Secure Door. This state will not allow access unless a Fire Unlock occurs.  
Fire Unlock. This state allows free access no matter what the previous door state or armed state is. This is a programmable  
option that can be used to allow free access into the building upon a fire alarm.  
Automatic Functions and Door State. The D9210B has two automatic functions that control door state based on the  
armed state of the area:  
Auto Door. With this function as [YES], the door will be unlocked when the area is disarmed.  
Disarm on Open. With this function as [YES], a user with valid access rights will activate the strike and disarm the system  
after the door is opened. With this function as [NO], the area will disarm upon the strike activation.  
2.1.1.3 Access Levels  
Armed State rights Users can be prevented from access depending upon the armed state of the area that the D9210B is  
assigned to. M-indicates the user has access no matter what the armed state, P- indicates the user has access as long as the  
Area is perimeter armed or disarmed and D-indicates the user only has access when the area is completely disarmed.  
Disarm Access Level. Users are allowed to disarm the area with an access id. Care should be taken to ensure that the user  
first has the authority to activate the strike based on the Armed State. P-indicates the user will disarm the area from  
Master to Perimeter Instant. D- indicates the user will disarm the area from Master or Perimeter to the disarmed state.  
2.1.1.4 Skeds  
Unlock Door. Provides an automatic free access at a specific time period. Requires a Lock Door Sked to return the door to  
normal. Can be overridden by manual control at the control center.  
Secure Door. Provides an automatic prevention of access at a specific time period. Requires a Lock Door Sked to return to  
normal. Can be overridden by manual control at the control center.  
Lock Door. Provides an automatic lock door state at a specific time to return the door to normal requiring valid  
cards/tokens to allow access.  
Message Suppression. Provides an automatic message off/on function at a specific time for Door and Access  
Granted or No Entry messages.  
Access Ctl Level On/Off. Provides an automatic on/off for each of the 14 levels dealing with the access control. Once a  
level is turned off, all doors are affected.  
Modular Design. The D9210B can be replaced by simply disconnecting the existing unit and connecting a new one with  
the same dipswitch setting. The panel will download stored data to the new unit when it is powered up and connected to  
the SDI bus.  
Diagnostics. Patterns of LED activation will indicate door state and ID validity. Other indications include SDI failure.  
(see Table 3: D9210B Diagnostic and Status LEDs, p.9).  
D9210B Operation and Installation Guide  
32206G  
Page 8  
© 2002 Bosch Security Systems  
 
D9210B  
D9210B Overview  
2.2  
Physical Overview  
Terminal Blocks. The D9210B comes  
with three banks of terminal blocks for  
connecting the D9210B to its power  
source, the panel and associated  
readers and relays.  
Relay  
D9210B  
1
PWR  
+
2
LCKN/C  
3
LCKCOM  
Relay. A removable (model D136)  
relay provides a dry contact single pull,  
double throw output.  
4
LCKN/O  
5
COM  
6
SDIA  
Terminal  
Blocks  
7
SDIB  
8
T
+
Dipswitch. The D9210B dipswitch has  
six on-off switch settings. Setting these  
switches allows each unique D9210B  
to be programmed for a specific  
address.  
9
ZNCOM  
10  
ZN  
+
DIP Switch  
ON  
11  
RTE  
1
2
3
4
5
6
12  
COM  
13  
REX  
14  
+5.20V  
15  
DATA  
0
16  
PROM. The D9210B is controlled by a  
programmable read-only memory  
microprocessor.  
DATA  
1
17  
BUZZER  
18  
LED  
PROM  
OPER  
MON  
Diagnostic and Status LEDs. The  
D9210B has a series of light emitting  
diodes (LEDs) for identifying  
operational and diagnostic states.  
These are listed below.  
Diagnostic and  
Status LEDs  
D0  
READER  
D1  
READER  
Figure 1: D9210B Access Control Interface Module  
LED  
Action  
State  
Operational Monitor (Green)  
LED blinks on and off  
LED is on or off (solid)  
LED rapidly blinking  
LED is off  
System is operational  
System is off or not operational  
Card data executing  
D0 Reader (Green)  
No card data is being received  
Card data executing  
D1 Reader (Yellow)  
LED rapidly blinking  
LED is off  
No card data is being sent  
Table 3: D9210B Diagnostic and Status LEDs  
2.3  
Basic Features, Displays and Reports  
2.3.1 Basic Features  
Highly reliable and simple to use  
Provides direct interface to 26-bit Weigand card readers.  
Interfaces with (up to eight) D9412 or (up to two) D7412 Control/Communicator panels  
Onboard buzzer output  
Card data LED indicators for low card data when valid format is read  
Operational LED which indicates the CPU is functioning and unit is powered  
Removable onboard relay for switching 12/24 VDC/VAC power  
Option to unlock or lock door upon SDI bus failure  
Supervised Onboard point  
Request to Exit and Request to Enter inputs that can have a shunt only option  
Easily programmable entry/exit door strike and shunt control  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 9  
32206G  
 
D9210B  
D9210B Overview  
Four door states: Locked, Unlocked, Secured, Fire Unlock.  
Disarm states using a token  
Pre-warn for holding door open too long  
Disarm system before or after a door opens  
Automatic Unlock door on disarm, Locked Door when armed  
Optional Deactivate strike when the door opened  
Interlock point assignment to prevent access until interlock point is normal.  
1000 Cards/Tokens  
Fourteen programmable levels of access authority  
Users can be added or deleted remotely, locally and with Command Center  
2.3.2 Displays and Reports  
Access Granted with user ID and User Name  
No Entry with user ID and door User Name  
Request to Enter with door point text  
Request to Exit with door point text  
Door Unlocked with door point text  
Door Locked with door point text  
Alarm Point ### with door point text  
Trouble Point ### with door point text  
Missing Point ### with door point text  
Please Close Door with door point text  
2.4  
Materials Included  
Bosch Security Systems ships the D9210B Access Control Interface module pre-assembled from the factory with a power  
supply, in its own can, or as a unit less can. You will receive the following parts with your package depending upon what  
model is ordered, (see Section 2.5 Ordered Separately, p.11).  
D136 removable relay mounted on the board.  
Battery Leads (for the D9210BLC).  
1 k1/2 watt end of line resistor.  
Literature Pack containing: D9210B Operation and Installation Guide (P/N:32206), D9210 Program Entry  
Guide (P/N:32207), ACCESS Program Record Sheet (P/N:32208), and Power Supply Installation  
Instructions.  
Hardware pack containing: three #6x3/8 self-tapping sheet metal screws to secure the module on the  
mounting skirt or the enclosure. Two strain relief cable ties.  
D9210B Operation and Installation Guide  
32206G  
Page 10  
© 2002 Bosch Security Systems  
 
D9210B  
D9210B Overview  
2.5  
Ordered Separately  
The D9210B Door Controller can be used with the Bosch Security Systems D7412 (supports 2 doors) or D9412 (supports  
8 doors) Control/Communicator security panels and associated control keypads and access control readers. Following are  
the available options.  
D9210BLC: The D9210BLC (up to 4) can be installed in the same enclosure as the control panel using the  
mounting screws and fasteners. Two additional modules can be mounted using the D136 brackets. Bosch  
Security Systems recommends that you use a separate power supply for the D9210Bs to isolate them from  
other SDI devices.  
D9210BC: The D9210BC is a complete unit mounted on a mounting skirt, (D9201M) with a 12 VDC (2.5  
A) power supply, and (1) D9210B. It can be installed with another D9210BLC in a single D8103, D8109 or  
D8108A enclosure.  
D9210B: The D9210B is mounted in a 8 in. x 5 in. x 3 in. (20 cm x 13 cm x 7.6 cm) (HxWxD) enclosure and  
can be mounted as a standalone unit in the field.  
Compatible Readers: Readers are not shipped with the unit (see Table 7: UL Listed Compatible Readers for  
the D9210B, p.18).  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 11  
32206G  
 
D9210B  
D9210B Overview  
2.6  
Listings and Approval Information  
2.6.1 Underwriters Laboratories (UL)  
The D9210B, when used with the D7412 or D9412 panels, is listed by UL for use as part of an Access Control System;  
Local, Police-Connect, Central Station, or Proprietary Burglar Alarm System; and a Commercial Fire Alarm System. In  
addition to the manual, refer to the D7412/D9412 installation documentation regarding Burglar Alarm Grades and Fire  
Alarm services supported. The D9210B is a Signaling Device Subassembly also suitable as a Burglar Alarm Unit Accessory  
Subassembly and Access Control Unit Subassembly.  
2.6.2 Other Listings and Approvals  
FCC 15B, CSFM (highrise)  
D9210B Operation and Installation Guide  
32206G  
Page 12  
© 2002 Bosch Security Systems  
 
D9210B  
Installation  
3.0 Installation  
Thank you for choosing our product. We have made an effort to identify the key steps for installing the D9210B  
successfully. To ensure that your installation goes smoothly, follow the installation steps in the order presented.  
3.1  
System Planning  
Before proceeding, draw your system layout on a sheet of graph paper. Also, review the architect and engineering  
drawings (if available). This will help you set addresses, mark the units, and route/tag wires. The drawing should include  
the Control Panel, the D9210B, the trip switches for RTE/REX, doors, readers, control centers assigned to the same area  
as the D9210Bs, and the wiring run.  
Have the following documents handy as you read through this manual:  
D9210B Program Entry Guide (P/N:32207)  
ACCESS Program Record Sheet (P/N:32208)  
Control/Communicator Program Entry Guide and Program Record Sheet  
Security System Owner’s Manual  
Power Supply Installation Instructions  
You should be familiar also with the operation of the D5200 programmer or the Remote Account Manager (RAM)  
remote programmer.  
3.2  
Procedure  
3.2.1 Mounting the Enclosure and Installing the D9210B  
Enclosure Placement. There is a 500 ft. (152 m) maximum distance allowed between the D9210B and Weigand card  
readers. Using 22 AWG (0.8 mm) wire, the D9210B may be remoted up to 2500 ft. (762 m) away from the control panel;  
using 18 AWG (1.2 mm) wire, the D9210B may be remoted up to 5000 ft. (1524 m). Consider placing the enclosure  
where a technician can gain easy access for troubleshooting the unit and where wiring can be routed easily.  
Preparing Knockouts. The D9210B requires six primary wire runs to be routed to the enclosure (see Table 4: Typical Wire  
Planning Chart for the D9210B, p.14). To identify the proper knockouts required, determine from which direction the  
panel, reader, door contact, door strike and the request to exit/enter wires will be coming. Run the necessary wiring  
throughout the premises and pull the wires into the enclosure. Avoid splicing and grouping wires together. Knock out the  
tabs for the wiring prior to mounting the enclosure.  
Mounting the Enclosure. When mounting the enclosure, place it against the wall and use a “level tool” to ensure the unit  
is level. Align the enclosure mounting holes with the vertical wood beams, usually 16 in. (41 cm) apart, to ensure a solid  
mount. With a pen or pencil, make marks where the top mounting holes expose the surface.  
Set the enclosure down and insert the mounting screws where the marks exist for the top left and right mounting holes.  
Leave a 0.25 in. (6.4 mm) gap between the wall and screw head so the enclosure can be hung on the screws.  
If vertical wood beams are not available, be sure to use the proper screw anchors and hardware to mount the  
unit.  
If any of the knockouts require that wire be run behind the wall, mark the holes and punch/drill them out prior to  
permanently installing the enclosure. After the holes have been knocked out and the enclosure is level, use all five  
mounting holes (three on the top and two on the bottom) to install the enclosure.  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 13  
32206G  
 
D9210B  
Installation  
3.2.2 Pulling and Marking the Wires  
Running wire. Use Table 4 to estimate the wire bundle size for your knockouts and where to mount the D9210B. Tag  
your wire runs to prevent confusion during installation and troubleshooting. Figure 2 shows the wiring for a typical  
D9210B installation.  
Suggested  
Wire Tag  
Approximate  
Diameter  
Recommended Wire Recommended  
Purpose  
Type  
Color Code  
Power/SDI data  
Tag A  
0.25 in.  
(6.4 mm)  
4/22 AWG quad  
(2500 ft. / 762 m)  
SDI:  
(Green)  
A
B
4/18 AWG quad  
(5000 ft. / 1,524 m)  
(Yellow)  
Pwr:  
+ (Red)  
- (Black)  
RTE power/input*  
REX power/input*  
Strike power*  
Door contact*  
Reader*  
Tag B  
Tag C  
Tag D  
Tag E  
Tag F  
0.25 in.  
(6.4 mm)  
4/22 AWG quad  
4/22 AWG quad  
2/16-18 AWG zip  
Green/Black  
Yellow/Black  
Red  
0.25 in.  
(6.4 mm)  
0.375 in.  
(9.5 mm)  
0.125 in.  
(3.2 mm)  
2/22 AWG  
(500 feet / 152 m)  
White  
0.375 in.  
(9.5 mm)  
6/22 AWG  
conductor  
(500 feet / 152 m)  
12 VDC: Red  
5 VDC: Orange  
COM: Black  
D1: White  
D0: Green  
LED: Brown  
Buzzer: Yellow  
+(Red), - (Blk)  
Buzzer*  
Tag G  
Tag I  
Tag J  
0.125 in.  
(3.2 mm)  
2/22 AWG twist  
2/18 AWG twist  
2/18 AWG zip  
Emergency Exit*  
0.125 in.  
(3.2 mm)  
Blue  
Power Supply  
Transformer  
0.25 in.  
(6.4 mm)  
Brown  
* Be sure to multiply the wires by the number of D9210Bs in the enclosure.  
Table 4: Typical Wire Planning Chart for the D9210B  
D9210B Operation and Installation Guide  
32206G  
Page 14  
© 2002 Bosch Security Systems  
 
D9210B  
Installation  
Strike and  
D9210B  
CAUTION  
12 VDC AUX  
Power Supply  
UL Listed for Fire  
DO NOT power the  
D9210B Module  
with 24 VDC.  
DC OUTPUT  
-
+
(red)  
EMERGENCY EGRESS Switch should be  
Normally Open (NO) for Coil Locks and  
Normally Closed (NC) for Maglocks  
D9210B  
(black)  
EMERGENCY  
EGRESS  
1
PWR +  
2
LCKN/C  
Security  
Panel  
3
LCKCOM  
4
LCKN/O  
5
SDI  
PWR  
COM  
6
(white/yellow)  
SDI  
A
SDIA  
SDI  
B
7
(green)  
(black)  
SDIB  
SDI  
COM  
8
T +  
TAMPER SWITCH  
(NORMAL OPEN)  
9
ZNCOM  
10  
ZN +  
DOOR CONTACT  
(NORMAL E.O.L.  
IN CIRCUIT)  
ON  
11  
RTE  
RTE/REX  
(NORMAL  
OPEN)  
1
2
3
4
5
6
12  
COM  
1K  
E.O.L.  
13  
REX  
(black)  
(red)  
14  
+5.20V  
DOOR  
15  
DATA 0  
(green)  
16  
DATA 1  
(white)  
17  
(yellow)  
(brown)  
BUZZER  
18  
LED  
12 VDC READER  
(+)  
12 VDC  
(-)  
DOOR  
STRIKE  
12 VDC  
BUZZER  
OPER  
MON  
Note: This color code does not match  
all readers. Make a note of the  
color code of the reader you are  
using.  
D0  
READER  
CAUTION Some jurisdictions will not allow the  
use of Emergency Egress as your sole  
means of escape. If this feature is used,  
it still may be necessary to provide listed  
panic hardware. Consult your local  
authority having jurisdiction (AHJ) prior to  
nstallation.  
D1  
READER  
A 24 VDC power supply may be used for the door  
strike if necessary. (See Figure 5)  
NOTE:  
Figure 2: Wiring Diagram for Typical D9210B Installation  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 15  
32206G  
 
D9210B  
Installation  
3.2.3 Mounting  
Do not install or replace a D9210B while it is connected to live power circuits. The D9210B should be  
powered down until it is ready to be tested.  
3.2.3.1 D9210BLC  
1. Mount the D8103, D8109 or D8108A enclosure on a flat service.  
2. Install another D9210LC to the mounting skirt (optional) prior to step 3.  
3. Hang the mounting skirt in the enclosure by aligning the rectangular tabs of the enclosure with the  
rectangular knockouts on the mounting skirt.  
4. Insert the #6x3/8 in. screw on the bottom tab of the mounting skirt and tighten 1/4 turn to seat it. This  
completes the mounting of the skirt in the enclosure.  
3.2.3.2 D9210B  
1. Remove the cover of the D9210B by loosening the two cover screws.  
2. Remove the required knockouts prior to replacing the cover.  
3. Mark the holes provided for mounting the bottom half of the unit to a wall or ceiling.  
4. Screw the provided screws in to the marked service and allow a 0.25 in. (6.4 mm) gap between the surface  
and bottom of the screw.  
5. Hang the unit and secure the screws. Replace the cover and cover screws.  
3.2.3.3 D9210BC  
1. The unit can be installed in a D8103, D8109 or D8108A enclosure by matching the three plastic mounting  
anchors to the three hole foot prints provided around the sides of the enclosure (4).  
2. The unit can be added to a D9210BC by matching the three plastic mount anchors to the available three  
hole foot prints below the factory installed D9210B.  
3. To secure the unit, use the three #8-3/4 in. screws provided.  
3.2.4 Door Contact (Onboard) Point, Terminals 9 and 10  
Voltage (VDC)  
0 - 1.2  
Description  
Description. The D9210B monitors the sensor loop  
between the input terminal 10 and the common terminal 9  
for normal, shorted, or open conditions. This loop is  
provided for a door contact. The maximum distance the  
Door Contact may be remoted from the D9210B is 500  
feet. The door contact can be programmed as a perimeter,  
interior, or 24 hour burglar alarm point.  
Loop shorted  
1.8  
Coming from a shorted condition,  
the D9210B restores the Door Point  
at 1.8 VDC  
2.65  
4.0 - 5.0  
3.5  
Normal loop voltage  
Loop open  
See the D9210B Program Entry Guide (P/N:32207) for  
assigning a point to the door controller and the panel  
Program Entry Guide for the point types.  
Coming from an open condition, the  
D9210B restores the Door Point at  
3.5 VDC  
Point Sensor Loop. Install a 1 kresistor at the door  
contact, not at the terminal of the input.  
Table 5: Point Tolerance Voltages  
This will provide supervision against grounds on the loop. You can connect only one contact, that being the door, to this  
input.  
Point Tolerances. Table 5 shows the voltages that determine the condition of the on-board point. Use the point common  
as your (-) reference when measuring the point (+). Set your meter for 10 to 24 VDC range.  
D9210B Operation and Installation Guide  
32206G  
Page 16  
© 2002 Bosch Security Systems  
 
D9210B  
Installation  
3.2.5 Door Lock, Terminals 2, 3 and 4  
State  
Description  
Description. A removable relay (model D136)  
provides a dry contact single pull double throw  
output. Some strikes require a closed circuit to  
unlock the door while others require an open  
circuit to unlock the door. The relay will  
support 12 VDC @ 2A or 24 VDC @ 2.5 A or  
12/24 VAC @ 40 A (See Table 6).  
Common Input (3) For 12/24 VDC strikes, provide the input power  
here from the power supply.  
Lock N/C (2)  
Lock N/O (4)  
For door strikes that require an interruption of  
power to open, connect the positive side of the  
door strike to this terminal.  
For door strikes that require power to open,  
connect the positive side of the door strike to  
this terminal.  
Table 6: Door Lock Strikes  
Relay Installation. The D136 Relay is installed into the relay socket of  
the D9210B. Follow these steps for installing the relay:  
D9210B  
1
E M N A  
R E R U T C A F U N M A  
PWR +  
1. Locate the relay socket on the D9210B board (shown in  
Figure 3).  
2
LCKN/C  
3
LCKCOM  
4
TOP  
LCKN/O  
2. Place the relay into the socket. The plug-in relay has two  
legs on the bottom and three legs on the top. When  
inserting the relay, ensure that it is oriented as shown in  
Figure 3.  
5
L
E M N A  
R E U R C A T F U N A M  
E
F
T
Figure 3: Relay Installation  
3.2.6 Request to Enter [RTE], Terminals 11 and 12  
Description. When Terminal 11 is momentarily shorted to Terminal 12, the strike is activated and the door point is  
shunted.  
Shunt Only: An option is provided that only shunts the point when this input is momentarily shorted. To activate the  
shunt, but not the strike, program RTE Shunt Only? as [YES].  
3.2.7 Request to Exit [REX], Terminals 13 and 12  
Description. When Terminal 13 is momentarily shorted to Terminal 12, the strike is activated and the door point is  
shunted.  
Shunt Only: An option is provided that only shunts the point when this input is momentarily shorted. To activate the  
shunt, but not the strike, program [REX] Shunt Only? as [YES].  
REX must not be used for emergency exit applications. NFPA 101 requires that a UL listed panic device be  
used to provide direct power from the standby power source. (see Figure 2: Wiring Diagram for Typical  
D9210B Installation, p.15 for wiring an emergency exit device). Check with your local Authority Having  
Jurisdiction (AHJ) prior to installing your system.  
3.2.8 Enclosure Tamper Switch, Terminals 8 and 9  
Description. A short to this loop will generate a Missing Trouble Point ### for the point number assigned to  
the D9210B. With this tamper point faulted, the D9210B will still function.  
Connect a N/O tamper switch to Terminals 8 and 9. Upon opening the enclosure, the tamper switch will short the inputs  
and generate the Missing Trouble Point ### message.  
SDI FAILURE ### and MISSING PT ### are reported to the central station when the SDI bus has  
failed or the D9210B is missing.  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 17  
32206G  
 
D9210B  
Installation  
3.2.9 Connecting the Card Reader, Terminals 12, 14, 15, 16, 17, and 18  
Description. These terminals provide connection for a standard 26-bit Wiegand reader.  
Compatible Readers: Table 7 specifies the UL listed Wiegand readers and associated tokens that are compatible with the  
D9210B. Bosch Security Systems guarantees only these readers will function properly and only the readers noted below  
can be used in UL certified systems.  
Model  
Voltage  
Description  
Tokens  
Cards  
Format  
D8201/  
D8201W  
+12 @ 35 mA  
Proximity, Low Profile,  
Black or White (W)  
D8238 proximity D8239 proximity  
26-bit  
D8203/  
D8203W  
+12 @ 35 mA  
Mullion Proximity, Black D8238 proximity D8239 proximity  
or White (W)  
26-bit  
D8227  
D8221  
D8223*  
D8224  
D8229  
+5 @ 35 mA  
+5 @ 25 mA  
+12 @ 175 mA  
+5 @ 80 mA  
+5 @ 120 mA  
Insert, Magnetic Stripe  
Swipe  
N/A  
N/A  
N/A  
N/A  
N/A  
D8230/D8240 magnetic stripe  
D8231 sealed magnetic  
D8236 proximity cards  
D8236 proximity cards  
N/A  
26-bit  
26-bit  
26-bit  
26-bit  
26-bit  
Proximity, Gray  
Proximity, slim, Gray  
Keypad reader  
* 12 V power from D9210B source  
Table 7: UL Listed Compatible Readers for the D9210B  
Readers can be mounted up to 500 ft. (152 m) from the D9210B module. A typical reader connection is shown in Figure  
2: Wiring Diagram for Typical D9210B Installation, p.15.  
Terminal 1, +12 VDC. The red wire is used to provide 12 VDC readers with power. Current is limited only by the source  
providing the power.  
Terminal 12, Common. The black wire provides the common for the reader. (Use this terminal when comparing other  
reader voltages.)  
Terminal 14, +5.25V. The orange wire is used to provide 5 VDC readers with power.  
Terminal 15, Data 0. The green wire is the carrier of binary one (1) pulses from the reader.  
Terminal 16, Data 1. The white wire is the carrier of binary zero (0) pulses from the reader.  
Terminal 17, Buzzer. The yellow wire is the common for the reader buzzer or external buzzer.  
Terminal 18, LED. The brown wire is the common for the reader LED.  
Note: The reader buzzer or common for the external buzzer can be used for Terminal 18 as an option.  
D9210B Operation and Installation Guide  
32206G  
Page 18  
© 2002 Bosch Security Systems  
 
D9210B  
Installation  
3.2.10 Setting the Dipswitch and Tagging the Unit  
The D9412 panel supports up to eight door controllers using all eight address settings. The D7412 supports up to two  
door controllers using the first two address settings. Each D9210B uses one of eight addresses. Addresses can not be  
duplicated. Because the D9210B is always supervised, two D9210B modules having the same address will not function  
and SDI failures will occur.  
Fill out the Program Record Sheet. Be sure the program record sheet for this door controller contains the area  
assignment, address assignment and control center assignment.  
Whenever possible, be consistent when numbering doors, control centers, and areas. This will help when  
programming a system with more than one door. (Example: Assign Door 1 to Area 1 and Control Center 1.)  
Technical  
Tip  
The D9210B dipswitch with factory default settings (all ON) is shown in Figure  
4. Table 8 shows the serial device reporting address settings for each door  
controller. Table 8 also shows dipswitch settings for Test and Fail modes.  
Figure 4: D9210B DIP Switch  
(Factory Settings)  
Fail  
Mode  
Door Controller Address  
1
2
3
4
5*  
6*  
Serial Device  
Control Center Display  
Central Station  
Modem IIIa2  
D9210 #1  
D9210 #2  
D9210 #3  
D9210 #4  
D9210 #5  
D9210 #6  
D9210 #7  
D9210 #8  
SDI #33  
SDI #34  
SDI #35  
SDI #36  
SDI #37  
SDI #38  
SDI #39  
SDI #40  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
ON  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
ON  
OFF  
OFF  
OFF  
OFF  
SDI Fail Mode  
SDI Fail – Door Unlocked  
SDI Fail – Door Locked  
---  
---  
---  
---  
---  
---  
ON  
OFF  
---  
---  
---  
---  
* Switches 5 and 6 must stay in the “ON” position  
Table 8: D9210B Dipswitch Settings  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 19  
32206G  
 
D9210B  
Installation  
3.2.11 Connecting Power and SDI, Terminals 1, 3, 5, 6, and 7  
Do not connect 24 VDC or non-isolated [from the strike] 12/24 VAC of the D9210B.  
Reference Figure 5 for the following connections.  
Terminal 1, Pwr +12 VDC IN. The red wire provides power to the D9210B, 12 VDC readers and buzzers.  
Terminal 3, LCKCOM. For 12/24 VDC strikes provide the input power here from the power supply.  
Terminal 5, Common. The black conductor provides electrical common between the D9210B and the power source.  
Always ensure a common exist from the D9210B to the panel so the power supply and panel have the same  
ground reference. Use any common terminal on the D9210B, 5, 9 or 12 for connections.  
Terminal 6, SDI A PANEL DATA (INPUT). The yellow conductor from the panel connected to this terminal. This is  
where data from the panel is received by the D9210B.  
Terminal 7, SDI B PANEL DATA IN (RETURN). The green conductor from the panel is connected to this terminal. This  
is where the data from the D9210B is returned back to the panel.  
24 VDC  
AUX Power  
Supply  
12 VDC AUX  
(Optional)  
Power Supply  
UL Listed for Fire  
DC OUTPUT  
DC OUTPUT  
(red)  
(red)  
D9210B  
D9210B  
(black)  
(black)  
1
1
PWR  
+
PWR  
+
2
2
LCKN/C  
LCKN/C  
Security  
Panel  
Security  
Panel  
3
3
LCKCOM  
LCKCOM  
4
4
LCKN/O  
LCKN/O  
5
5
SDI  
COM  
SDI  
COM  
PWR  
PWR  
6
6
(white / yellow)  
SDI  
A
SDIA  
(white / yellow)  
SDIA  
SDI  
A
SDI  
B
7
SDI  
B
7
(green)  
(black)  
SDIB  
(green)  
(black)  
SDIB  
SDI  
COM  
8
8
T +  
SDI  
COM  
T
+
9
9
ZNCOM  
ZNCOM  
10  
10  
ZN  
ZN  
+
+
Note: In installations where powering the  
D9210B with the security panel is impractical,  
a 12 VDC power supply can be substituted.  
Figure 5: Power Supply and SDI Connections  
It is very important to include your strike current. Bosch Security Systems recommends you use an auxiliary  
power supply to isolate door controls and ensure the integrity of the system.  
Technical  
Tip  
3.2.12 Programming and Activating the D9210B  
Description. The D9210B needs to be assigned to an area before it will communicate properly with the panel. In addition,  
the dipswitch settings and the power need to be connected.  
The dipswitch settings in Table 8: D9210B Dipswitch Settings, p.19 determine the address of the D9210B. At the top of the  
ACCESS Program Record Sheet (P/N:33208), the address number (noted next to the dipswitch setting in Figure 4: D9210B  
DIP Switch  
(Factory Settings), p.19) will determine which parameters for the door controller are sent.  
D9210B Operation and Installation Guide  
32206G  
Page 20  
© 2002 Bosch Security Systems  
 
D9210B  
Installation  
To activate the D9210B, follow the instructions in the D9210B Program Entry Guide (P/N:32207). Use the ACCESS  
Program Record Sheet to match the door to the proper address and to ensure that the door is assigned to the proper area.  
3.2.13 Step 13: Testing the D9210B  
Description. The D9210B comes shipped with a default program that will let you run a quick test upon installing the  
unit. Go through the following items to verify the D9210B is functioning properly. If you have problems, see Table 9:  
LED Troubleshooting Guide, p. 25.  
D9210B: Verify that the Operational Monitor LED is pulsing approximately once every second. This indicates the  
microprocessor is running. Go to the Unlock Door function. A number from 1 to 8 should appear for the door controller.  
If an F appears, the unit has failed or is not responding correctly to the panel’s polls.  
Zone: Using the Control Center, verify the point is normal when the door is closed, the point goes off normal when the  
door is opened and a shunt is not applied, and that the point stays normal upon opening the door on a valid access  
granted.  
Strike: Read a valid token to activate the strike. If tokens have not been added, use the Door Control, Door Unlock mode  
to cycle the strike. In addition, you will cycle the strike when you test the [RTE/REX] inputs (if shunt only is not  
programmed [YES].  
RTE/REX: Fault these inputs to activate the strike. The default for the strike time is 10 seconds. Test each separately.  
Buzzer: The buzzer should have sounded on each strike activation. Also hold the door open past the normal shunt time  
and ensure the Extend Buzz functions.  
Reader: Depending on the reader, the reader LED will be red upon powering up the D9210B. During the above tests, it  
will turn green anytime the strike is activated.  
To verify the reader, check and see that the D1 and D0 LED’s blink rapidly while a card is passed through the reader or a  
token is held up to the proximity reader.  
For other LED functionality, see Table 9: LED Troubleshooting Guide, p. 25.  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 21  
32206G  
 
D9210B  
Installation  
Notes:  
D9210B Operation and Installation Guide  
32206G  
Page 22  
© 2002 Bosch Security Systems  
 
D9210B  
Operation  
4.0 Operation  
4.1  
Door Release Application  
The D9210B can be used for door  
release functions. When used in  
this configuration, the strike relay  
contacts must be supervised. This  
can be accomplished with the use  
of an end-of-line relay commonly  
used for smoke detectors.  
RELAY  
-
D9210B  
AUX POWER  
UL Listed for Fire  
1
PWR +  
Connecting the D9210B for this  
application is shown in Figure 6.  
2
LCKN/C  
3
LCKCOM  
POPIT  
Program Point Index in the  
POINTS handler as Supervisory  
with Point Response as [A]  
Supervisory on Open and Trouble  
on Short.  
4
LCKN/O  
5
COM  
6
SDIA  
DOOR A  
7
SDIB  
8
T +  
The power supply, end-of-line  
relay, and the D9210B must be in  
the same enclosure or adjacent  
enclosures connected via conduit  
not longer than 20 ft. (6 m).  
9
ZNCOM  
10  
ZN +  
(-)  
11  
RTE  
12  
COM  
(+)  
MAGNETIC  
DOOR HOLDER  
Figure 6: D9210B Door Release Application Connections  
Note: When using the D9210BC, you must use the D8004 Transformer Enclosure for the power supply transformer.  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 23  
32206G  
 
D9210B  
Operation  
Notes:  
D9210B Operation and Installation Guide  
32206G  
Page 24  
© 2002 Bosch Security Systems  
 
D9210B  
Troubleshooting  
5.0 Troubleshooting  
5.1  
LED Troubleshooting  
Use the following reader and D9210B LED patterns to troubleshoot the D9210B. It is important to use the Door Control  
function to validate actual door states when troubleshooting.  
Reader Action  
If Reader LED is  
then Door State is  
so LED will toggle  
Idle reader LED  
Red  
Locked  
Red  
Secured  
Unlocked  
Green  
Continuous Red/Green  
Locked on Fail (Dipswitch  
optional)  
SDI disconnected,  
D9210B is not  
programmed with an  
area, D9210B faulty.  
Unlocked on Fail  
(Dipswitch optional)  
Access Granted  
Access Denied  
Red: Valid token to activate  
strike.  
Locked  
Red to Green for  
duration of strike time.  
Green: Valid token will not  
activate strike because strike  
is latched to allow access.  
Unlocked  
Green to Red to Green  
Red: Valid token format not  
added.  
Locked  
Locked  
Secured  
Red to Green to Red  
(pattern repeats twice)  
Red: Valid token but level is  
turned off.  
Red to Green to Red  
(pattern repeats twice)  
Red: No access allowed  
regardless of level because  
door is secured.  
Red to Green to Red  
(pattern repeats three  
times)  
Custom Function  
Adding IDs  
Red: Valid token will run.  
Green: Valid token will run.  
Locked/Secured  
Unlocked  
Red to 1 second Green to  
Red  
Green to 1 second Red to  
Green  
Red: Adding new token  
Learn Mode while door is  
secured or locked.  
Red to 2 second Green  
back to Red  
Red: Changing token that  
exists.  
Learn Mode while door is  
secured or locked.  
Red to Green to Red to  
Green to Red  
Green: Changing token that  
exists.  
Learn Mode while door is  
unlocked.  
Green to 1 second Red to  
Green  
Green: Adding new token  
Learn Mode while door is  
unlocked.  
Green to 2 second Red to  
Green  
Table 9: LED Troubleshooting Guide  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 25  
32206G  
 
D9210B  
Troubleshooting  
Notes:  
D9210B Operation and Installation Guide  
32206G  
Page 26  
© 2002 Bosch Security Systems  
 
D9210B  
Appendix A: D9210B Terminal Quick Reference  
and Electrical Specifications  
Appendix A: D9210B Terminal Quick Reference  
and Electrical Specifications  
Description  
Terminal  
Electrical Specifications  
1
PWR +  
12 VDC power input  
8.5 - 13.8V [depending on reader draw: 110  
mA (board) + 150 mA (reader max) = 260 mA]  
2
3
LCK N/C  
Continuity with LCK COM when relay is off.  
12/24 V @ 2.0 A max (30 VDC max)  
LCK COM  
Input to feed LCK N/C (T2) and Lock N/O  
(T3)  
4
LCK N/O  
Continuity with LCK COM when relay is on.  
12/24 V @ 2.0 A max (30 VDC max)  
5
6
COMMON  
SDI A  
Common Input (power for lock and device)  
Data from the panel to the D9210B  
high impedance bi-directional differential bus  
7
8
SDI B  
T +  
Data back to the panel from the D9210B  
Positive input for Tamper, normally open  
RS-485 @ 9600 baud  
open collector input 1 kpull up  
V in < 1.8 V on > 3.2 V off  
9
ZNCOM  
Common input for on-board point  
Positive Input for on-board point  
1K termination resistor between T9 and  
T10 required  
1
0
ZN +  
RTE  
1
1
Input from Request to Enter (RTE) momentary  
short device  
open collector input 1kpull up  
V in < 1.8 V on > 3.2 V off  
1
2
COM  
REX  
Common input for REX/RTE devices  
1
3
Input from Request to Exit (REX) momentary  
short device  
open collector input 1 kpull up  
V in < 1.8 V on > 3.2 V off  
1
4
+5.2 V  
Power out to 5.2 VDC card reader.  
V out 5 V .25 V for 20 - 140 mA load  
150 mA maximum continuous  
1
5
DATA 0  
Data 0 input from card reader (activates D0  
LED)  
high impedance differential inputs with 10 kΩ  
pull up to +5.2 V  
1
6
DATA 1  
Data 1 input from card reader (activates D1  
LED)  
1
7
BUZZER  
Buzzer common upon strike activation.  
sink up to 35 mA from 5 - 14 VDC source  
output impedance is 100 Ω  
1
8
LED  
LED common upon card read response and  
strike activation.  
sink up to 35 mA from 5 - 14 VDC source  
output impedance is 180 Ω  
Table 10: Terminal Quick Reference Guide and Electrical Specifications  
D9210B Operation and Installation Guide  
© 2002 Bosch Security Systems  
Page 27  
32206G  
 
© 2002 Bosch Security Systems  
130 Perinton Parkway, Fairport, NY 14450-9199 USA  
Customer Service: (800) 538-5807; Technical Support: (888) 886-6189  
32206G  
Operation and Installation  
Guide  
10/02  
D9210B  
Page 28 of 28  
 

Black Decker Drill 1575 10 User Manual
Black Decker Oven CTO4600BCUC User Manual
Blanco Oven BOSE45X User Manual
Bosch Appliances Home Security System DS938Z User Manual
Briggs Stratton Automobile Parts 25100 User Manual
Briggs Stratton Building Set 60700 60706 User Manual
Briggs Stratton Car Seat S200X User Manual
ButtKicker Stereo Amplifier BKA1000 4A User Manual
Chariot Carriers Bicycle Accessories 2001 TCT CADDLE User Manual
Chrysler Automobile Alarm CHDL3 User Manual